Solar panels in the garden
Break free from high electricity bills
The structure must be sound
The basic requirement for installing PV systems is that the kit must have sufficient structural integrity. You should therefore check whether the kit you have chosen is designed to withstand the required snow load and support a PV system. For solar panels and their mounting structure, you should allow for approximately 0.15–0.35 kN/m². For many kits, we offer optional roof reinforcements.
Many of our kits are suitable for installing solar panels for PV systems
Flat roofs with timber boarding and EPDM membrane
When installing a PV system on a flat roof with timber boarding, we recommend using an EPDM membrane as the roof covering. You can install a PV system on this very sturdy membrane without the need for ‘roof penetration’. The PV system’s mounting frames are secured against strong winds using paving slabs or kerbstones, for example.
Gable or monopitch roofs with roof tiles or steel sheets
Our gable and monopitch roofs are available with roof battens for fitting roof tiles or steel roofing sheets, or with roof boarding for fitting roof shingles.
We recommend the ‘roof battens’ option. For roof tiles or steel roofing sheets, there are many pitched roof systems that allow for the installation of PV systems.
Good to know:
Structural analysis
The basic prerequisite for the installation of PV systems is that the kit is structurally sound. Our kits are structurally designed to withstand a specific snow load (per square metre). For the location where your kit is installed, there is a specified snow load that is mandatory for the construction project. You can find out the local snow load from your local planning authority or, for example, here:https://www.dlubal.com/de/loesungen/online-dienste/schnee-wind-erdbeben-lastzonen
The difference between the snow load specified for the kit and the prescribed snow load gives the maximum roof load for the solar panels.
Example of snow load: Friesland carport
The snow load for a carport is 1.25 kN/m² and the locally specified snow load is, for example, 0.85 kN/m². This leaves you with a margin of 0.4 kN/m² for the structure supporting the solar modules. If this margin is insufficient, optional snow load components can be ordered for many of our kits.
Example of snow load: Friesland carport
An optional snow load of up to 2.00 kN/m² can be ordered. The margin would then amount to 1.15 kN/m².
2.00 kN/m² Snow load of the kit
0.85 kN/m² : Local snow load
—————
1.15 kN/m² : Reserve for solar panels and structure
For solar panels and their substructure, allow for approximately 0.15 – 0.35 kN/m².
This value depends on the structure you have chosen.